Data Centers

Replace the UPS with InnoX Energy's integrated liquid-cooled energy storage system capable of 1C charging and discharging. Only 1/4 of the battery capacity (enough for 15 minutes of power supply) needs to be reserved to support the startup and connection of the diesel generator when the grid power fails. That is, the depth of discharge of the system is controlled at 25%. The remaining 75% of the battery capacity can be used for peak-valley arbitrage in the daily power consumption of the data center.

BackgroundIntroductionBusiness Values Product Portfolio
Background

Data centers are equipped with diesel generators to deal with power outages from the power grid. However, it takes a certain amount of time for the diesel generators to start after a power outage. Therefore, an uninterruptible power supply (UPS) needs to be installed to provide support for 15 minutes to ensure that the diesel generators can be started and switched in. This power supply uses lead-acid batteries as the storage medium. Since their service life is short, they need to be replaced frequently.

Introduction

Replace the UPS with InnoX Energy's integrated liquid-cooled energy storage system capable of 1C charging and discharging. Only 1/4 of the battery capacity (enough for 15 minutes of power supply) needs to be reserved to support the startup and connection of the diesel generator when the grid power fails. That is, the depth of discharge of the system is controlled at 25%. The remaining 75% of the battery capacity can be used for peak-valley arbitrage in the daily power consumption of the data center.

Business Values
Lithium batteries replace traditional lead-acid batteries
Lithium batteries replace traditional lead-acid batteries

The service life of lead-acid batteries is 2 years, and they require regular maintenance and replacement. The service life of lithium batteries can reach more than 10 years. The comprehensive cost of using lithium batteries is much lower than that of lead-acid batteries, and it can also reduce environmental pollution.

Peak-valley arbitrage
Peak-valley arbitrage

The energy storage system can earn substantial income through peak-valley arbitrage.

Additional revenue
Additional revenue

By connecting to the VPP (Virtual Power Plant) and accepting the dispatching of the power grid, additional revenue can be generated.

Product Portfolio
  • Liquid-cooled ESS

    Liquid-cooled ESS

    241kWh Large-surface Liquid Cooled

  • All-liquid-cooled ESS

    All-liquid-cooled ESS

    Fully Liquid Cooled Battery Pack

  • Distributed Modular ESS

    Distributed Modular ESS

    Safe and Reliable


    Phone: +86 15945779939 E-mail: sales01@innoxenergy.com Address: No.19 Zhuoyue Road, Longxing Town, Liangjiang New Area, Chongqing, China
  
CopyRight © 2025 InnoX Energy Technology B.V. All Rights Reserved.